Half-Hour Protection:
| 1. |
Cut a 95mm dia hole in the required location in the ceiling tile. |
| 2. |
Curve the metal strip round as shown in fig. 1 and secure with the self-adhesive tape supplied to form the outer shield. |
| 3. |
Offer the shield up into the ceiling hole and bend over the tabs as shown in fig. 2 to secure. |
| 4. |
Fit the luminaire as detailed below. |
One Hour Protection:
| 1. |
Cut a 95mm dia hole in the required location in the ceiling tile. |
| 2. |
Offer the stay up through the ceiling hole. Where possible, the stay should be supported on the Tee Grid or a cross beam. |
| 3. |
Curve the metal strip round as shown in fig. 1 and secure with the self-adhesive tape supplied to form the outer shield. |
| 4. |
Offer the shield up into the ceiling hole and through the hoop in the stay as shown in fig. 3. |
| 5. |
Bend the tabs over the stay and onto the back of the ceiling tile to secure. |
| 6. |
Fit the luminaire as detailed below. |
Luminaire Fitting:
All electrical termination must be carried out by a qualified electrician in accordance with the latest IEE wiring regulations BS7671.
| 1. |
Remove the tape backing on the rear of the bezel. |
| 2. |
Tension both springs to the vertical position and pass the luminaireup into the cut-out. |
| 3. |
Press the bezel firmly into place to ensure that the tape bonds correctly with the ceiling. |
| 4. |
Insert the lamp, after first checking the correct wattage and pin configuration. |
Replacement Lamps
Osram Dulux T/E Lumilux, Cool White, 18W or 26W.
For replacement lamps call 01527 831794.
< Back to Emerald page
|